Friday, May 24, 2019
Nitrophenol Essay
Abstract Using a micro scale go distillation we se paratrooperted ortho and para-nitrophenol from a mixture that was already made. After the para and ortho were uncaring we measured their melting points and compargond it to the literature values for purity. For ortho-nitrophenol we had 60% recovery and for para 160% recovery. Our melting point ranges were ortho 45-46C and para 64-95C.IntroductionNitration In phenols, -OH group strongly activates the ring system. As a result, phenols are susceptible to oxidisation in the presence of concentrated nitric acid (HNO3). Thus, nitration of phenols is carried out with dilute nitric acid and results in the formation of o-nitrophenol and p-nitrophenol. The o-nitrophenol is steam volatile and the mixture of o-nitrophenol and p-nitrophenol is separated by steam distillation, in our case using micro scale measurements for safety and time consumption purposes.(Electrophilic aromatic substitution) We used steam distillation because we are distil ling under 100C above 100C is H2O. Looking at the volatility of o-nitrophenol compared to p-nitrophenol, the p-nitrophenol has intermolecular hydrogen bonding and it occurs due to a commodious number of molecules are associated together. This association in the p-isomer makes it less volatile. However in o-nitrophenol, intramolecular hydrogen bonding occurs and thus, it exists in a monomolecular state making it to a greater extent volatile.Results/Discussion Using a sand bath for transferring of heat through the distillation which was sitting on a hot plate. Using a humiliated round bottom flask which was attached to Hickmans distillation head and then we attached water through the openings. Using 1.00g of the prepared mixture we move it in the round bottom flask on with 1.00mL of ethanol and then filled it about 2/3 with water. We added a magnetic spin-vane to the flask as well. We collected the yellow waxy ortho-isomer from groove in Hickmans distillation head using a Pasteur pipette.We made sure that the solids did not accumulate as this would clog the condenser. If it did we would just turn off the cold water momentarily and the hot vapor would melt the solid. The distillation took about 45 minutes and sluice though this was the specified time period for distilling the mixture, we felt as though much of the ortho-isomer was left in the small round bottom flask along with the para-isomer and the spin valve. In order to characterize the 2- and 4-nitrophenols, we need to determine their melting points. We compared our results to those in the literature.Data*some ortho solidified in the Pasteur pipette so on that point might arise a percent error from this as some ortho was left in there. *we assumed that the starting mixture was about 50% for each one of o- and p-nitrophenol.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.